TitleProduct

EVI Inverter Heat Pump for Commercial

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Shandong

  • Validity to:

    Long-term effective

  • Last update:

    2024-02-07 20:40

  • Browse the number:

    231

Send an inquiries

Company Profile

Airsour Co., Ltd

By certification [File Integrity]

Contact:sdars(Mr.)  

Email:

Telephone:

Phone:

Area:Shandong

Address:Shandong

Website:http://www.airsour.com/ http://sdars.szhx99.com/

Product Details


Advantages


 



There are several advantages of using the EVI inverter heat pump for comme rcial use. Firstly, the system is highly energy-efficient, which means that it can help you save on your heating and cooling costs. Secondly, it provides excellent temperature control, ensuring that you are always comfortable inside your building. Thirdly, the system is easy to install and operate, making it an excellent choice for commercial buildings of all sizes.



 





 




Impact On Society


 



The EVI inverter heat pump for commercial use has a significant impact on society in several ways. Firstly, the system helps to reduce energy consumption, which helps to reduce greenhouse gas emissions and protect the environment. Secondly, the system improves indoor air quality, which has a positive impact on public health. Thirdly, the system provides economic benefits by helping commercial building owners reduce their energy costs and improve their bottom line.



 




Application And Usage


 



The EVI inverter heat pump for commercial use is suitable for a wide range of commercial and industrial applications, including office buildings, hospitals, schools, supermarkets, and manufacturing facilities. The system can be used for both heating and cooling and can provide consistent and reliable performance even in extreme weather conditions.



 



In conclusion, the EVI inverter heat pump for commercial use is an excellent choice for commercial building owners who want an energy-efficient and reliable heating and cooling system. The system provides several advantages and has a significant impact on society by reducing energy consumption, improving indoor air quality, and providing economic benefits. With its easy installation and operation, it is a smart choice for commercial buildings of all sizes.



 
























































































































































































































Unit Model DKX(L)RS-108Ⅱ/LC DKX(L)RS-108Ⅱ/VC DKX(L)RS-216Ⅱ/UC  
Power supply specifications 380V/3N~50Hz 380V/3N~50Hz 380V/3N~50Hz  
Nominal heat production

Dry bulb -12 degrees

Wet bulb-14 degrees



 
Nominal heat production(KW) 60 60 120  
Nominal heating input power(KW) 23.2 23.2 49  
Nominal current(A) 46.4 46.4 96  
Energy efficiency ratio 2.6 2.6 2.6  
Nominal cooling

Dry bulb 35 degrees

Wet bulb 24 degrees
Nominal cooling capacity(KW) 68 68 140  
Nominal refrigeration input power(KW) 23.6 23.6 52  
Nominal current(A) 47.4 47.4 104  
Energy efficiency ratio 2.71 2.71 2.7  
Heat production Rated water discharge temperature℃ 41 41 41  
Max. water discharge temperature℃ 58 60 58  
Refrigeration Rated water discharge temperature℃ 7 7 7  
Max. Power Input(kW) 34 34 65  
Max. Current Input(A) 68 68 130  
Waterproof grade IPX4 IPX4 IPX4  
Compressor Copeland 2*286HSP Scroll Copeland 2*150KS Scroll Copeland 4*286HSP Scroll  
Refrigerant (charge quantity) R410A/8.5 R22/2*10 R410A/4*8.5  
Waterway side Type Shell tube Shell tube Shell tube  
Inlet and outlet water pipe size 2" / DN50 external teeth 2" / DN50 external teeth 2.5" / DN65 flange  
Circulating water flow(m³\h) 18.5 18.5 37  
Main pipe diameter DN50 DN50 DN65  
Water-side pressure loss(kPa) ≤70 ≤70 ≤82  
Power cord specifications 25 square copper wire 25 square copper wire 35 square copper wire  
Dimension 2000*1000*1630 2030*1100*2120 2300*1300*2390  
Net weight of the unit(kg) 740 740 1120  
Gross weight of the unit(kg) 790 790 1170  
Operating noise(dB(A)) <76dB(A) <76dB(A) <85dB(A)  



 






Installation Instructions


 



1. The PPR pipe is used to connect between the unit and the water tank.



2. The host wiring should be connected to the external air switch before connecting to the main power supply, the power cord using international copper wire.



3. Fruit warming circulating water pump wire should be floor into the machine Tan drink sub plate (sub plate has been pre Lei water system row mouth and zero line interface), the pump for 220V power supply. Current more than 5A or 380V need to be connected to external AC contactor.



4. Buffer energy pump water pump should be connected to the pressure field flow and head root dig customer actual use situation.



5. The system control by the unit inside plus control board control machine machine machine machine water tank probe should be put into the water tank probe temperature blind tube in the eye must broadcast car should be fixed in the Department.



6. All outdoor hot and cold water pipe application special outdoor moisture pipe.



7. Tap water inlet water needs to do softening treatment, inlet water pipeline well anti-freeze.



8. The host fixed in the base surface need to do the degree of reduction when the pump and the support set fixed also need to do shock absorption, the pump placed in the outdoor need to do rain cover.

http://www.airsour.com/